[fusion_builder_container hundred_percent=”no” equal_height_columns=”no” menu_anchor=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” background_color=”” background_image=”” background_position=”center center” background_repeat=”no-repeat” fade=”no” background_parallax=”none” parallax_speed=”0.3″ video_mp4=”” video_webm=”” video_ogv=”” video_url=”” video_aspect_ratio=”16:9″ video_loop=”yes” video_mute=”yes” overlay_color=”” video_preview_image=”” border_color=”” border_style=”solid” padding_top=”” padding_bottom=”” padding_left=”” padding_right=”” type=”flex”][fusion_builder_row][fusion_builder_column type=”1_1″ layout=”1_1″ background_position=”left top” background_color=”” border_color=”” border_style=”solid” border_position=”all” spacing=”yes” background_image=”” background_repeat=”no-repeat” padding_top=”” padding_right=”” padding_bottom=”” padding_left=”” margin_top=”0px” margin_bottom=”0px” class=”” id=”” animation_type=”” animation_speed=”0.3″ animation_direction=”left” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” center_content=”no” last=”true” min_height=”” hover_type=”none” link=”” border_sizes_top=”” border_sizes_bottom=”” border_sizes_left=”” border_sizes_right=”” first=”true”][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=”default” rule_size=”” rule_color=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=””]

Transformer Turns Ratio Testing: TTR Meter

Transworld Electric is a full service electrical contractor offering de-energized and energized electrical testing services in South Carolina and Georgia. All electricians are licensed with the necessary training and qualification required to service your electrical system.

Contact Transworld Electric for all of your Transformer Turns Ratio (TTR) testing needs.

[/fusion_text][fusion_button link=”/contact” text_transform=”” title=”” target=”_self” link_attributes=”” alignment=”center” modal=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” color=”custom” button_gradient_top_color=”” button_gradient_bottom_color=”” button_gradient_top_color_hover=”” button_gradient_bottom_color_hover=”” accent_color=”#ffffff” accent_hover_color=”#ffffff” type=”” bevel_color=”” border_width=”” size=”” stretch=”default” icon=”” icon_position=”left” icon_divider=”no” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” border_radius=”” border_color=”#ffffff” border_hover_color=”#ffffff”]SCHEDULE TODAY[/fusion_button][fusion_separator style_type=”none” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” sep_color=”” top_margin=”” bottom_margin=”” border_size=”4″ icon=”” icon_circle=”” icon_circle_color=”” width=”” alignment=”center” /][fusion_youtube id=”https://www.youtube.com/watch?v=EOyahzuz35U&t=1s” alignment=”center” width=”” height=”” autoplay=”true” api_params=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” css_id=”” /][fusion_text columns=”” column_min_width=”” column_spacing=”” rule_style=”default” rule_size=”” rule_color=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=””]

WHAT IS A TRANSFORMER TURNS RATIO METER?

A transformer turns ratio meter (TTR Meter) is used to test ratio accuracy of a transformer. A TTR Meter works by applying an AC low voltage test to the primary coils of the transformer and then reads the ratio of the secondary coils. By using Ohms law, it divides the voltage on your primary coil by the voltage of your secondary and gives calculates the ratio. There are 3 styles of TTR meters that include single-phase models, 3 phase and PT and Ct (Current Transformers) & PT (Potential Transformers) meters.

WHAT ARE THE BENEFITS OF TRANSFORMER TURNS RATIO TESTING?

The benefit of performing a TTR test is that it can confirm that the transformer has the correct ratio of primary to secondary turns. If the test is used correctly, it can help identify tap changer performance, shortened turns, open winding, incorrect winding connections and other faults inside transformers. This important because it can tell you the health of your transformer and diagnose diagnose issues such as a bad coil or explain some voltage irregularities that you may be experiencing.

For all of your electrical testing needs, call Transworld Electric today!

Transworld Electric is a full service electrical contractor charleston South Carolina. We have an unlimited electrical licensed in SC, NC, & GA. 

[/fusion_text][fusion_button link=”/contact” text_transform=”” title=”” target=”_self” link_attributes=”” alignment=”center” modal=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” color=”custom” button_gradient_top_color=”” button_gradient_bottom_color=”” button_gradient_top_color_hover=”” button_gradient_bottom_color_hover=”” accent_color=”#ffffff” accent_hover_color=”#ffffff” type=”” bevel_color=”” border_width=”” size=”” stretch=”default” icon=”” icon_position=”left” icon_divider=”no” animation_type=”” animation_direction=”left” animation_speed=”0.3″ animation_offset=”” border_radius=”” border_color=”#ffffff” border_hover_color=”#ffffff”]SCHEDULE TODAY[/fusion_button][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container]